8
CONTROL PANEL11.
Voltage Selector Switch
This charger has a voltage selector switch on the front of it. Match the charging
voltage (6 or 12 volts) to the voltage of the battery being charged.
Circuit Breaker
This charger is equipped with an internal self-resetting circuit breaker. The
breaker protects the charger from temporary overloads. In the event of an
overload, the breaker will trip open and after a short cooling off period, will
reset automatically. This process is known as cycling and can be recognized
by an audible clicking sound. If the circuit breaker is cycling, see the
TROUBLESHOOTING section.
OPERATING INSTRUCTIONS12.
Charging
Ensure that all of the charger components are in place and in good 1.
working condition, including the plastic boots on the battery clips.
Connect the battery following the connection instructions described in 2.
Using the Quick-Disconnect Cable Connectors section.
Connect the AC power following the precautions listed in Section 8.3.
USING THE QUICK-CONNECT CABLE CONNECTORS
Connect either of the two output cable assemblies to the charger in seconds.
Makesuretoplacethechargeronadry,non-ammablesurfacelikemetalor
concrete.
NOTE: Never connect the clip and ring terminal connectors together for use in
other applications, such as external battery or other power source charging, or to
extend the output cable length, as reverse polarity and/or overcharge conditions
will occur.
BATTERY CLIPS: Connect the battery clip cable assembly to the charger. Follow
the safety instructions in sections 6 or 7 to connect the output clips to the battery.
RING TERMINALS: The ring connectors permanently attach to the battery
providing easy access to quickly charge your battery. This application is
appropriate for motorcycles, lawn tractors, ATV’s and snowmobiles. To
permanently attach it to a battery, loosen and remove each nut from the bolts at
the battery terminals. Connect the red positive ring connector ring to the positive
(POS, P, +) battery terminal. Connect the black negative ring connector ring to
the negative (NEG, N, -) battery terminal. Replace and tighten the nuts to secure