Schumacher Electric SSC-1500A Owner's Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
11
USING YOUR BATTERY CHARGER
OVERVIEW
Using the battery charger is very simple.
First, connect the battery and AC power
following the precautions listed under
“OPERATING INSTRUCTIONS”. Then
select the appropriate BATTERY TYPE
and BATTERY SIZE for your battery. The
charger will then do everything automati-
cally.Thissectionexplainsafewdetails.
CHARGING: If the charger does not
detect a properly connected battery, the
CONNECTED(red)LEDwillnotlight
continuously until a battery is detected.
Charging will not begin until the CON-
NECTED LED comes on. When charging
begins, the CHARGING LED will be lit.
AUTOMATIC SHUT OFF: When the 2A
SMALL, 10A MEDIUM, or 15A LARGE
BATTERY SIZE is selected, the charger
is set to perform an automatic charge.
When an automatic charge is performed,
the charger stops charging automatically
after the battery is fully charged.
ABORTED CHARGE: If charging can’t
be completed normally, charging will be
aborted. When charging is aborted, the
charger’s output is shut off and all the
LED'sareoffexcepttheCONNECTED
LED. In this state, the charger ignores
all buttons. To reset after an aborted
charge, either disconnect the battery or
unplug the charger.
DESULFATION MODE: If a battery is
leftdischargedforanextendedperiod,it
could become sulfated and not accept a
normal charge. If the charger detects a
sulfated battery, the charger will switch to
a special mode of operation designed for
such batteries. Activation of the special
desulfationmodeisindicatedbyblink-
ing the CHARGING LED. If successful,
normal charging will resume after the
battery is desulfated. The CHARGING
LEDwillthenstopblinkingandlightcon-
tinuously.Desulfationcouldtakeupto10
hours. If desulfation fails, charging will
beabortedandtheCONNECTED(red)
LED will remain lit.
COMPLETION OF CHARGING:
Charge completion is indicated by the
CHARGED(green)LED;whenlit,the
charger has stopped charging and
switched to the Maintain Mode of opera-
tion.
MAINTAIN MODE: When the CHARGED
(green)LEDislit,thechargerhas
started Maintain Mode. This mode of
operationisalsoknownasFloat-Mode
Monitoring. In this mode, the charger
keepsthebatteryfullychargedby
delivering a small current, when neces-
sary. The voltage is maintained at a
level determined by the BATTERY TYPE
selected.
GENERAL CHARGING NOTES:
The fan runs whenever the charger is
plugged into a 120V AC outlet.
If the charge mode is changed after
charginghasstarted(bypressingthe
BATTERY SIZE or BATTERY TYPE
button),thechargingprocesswillbe
restarted.
The voltage displayed during charging is
the charging voltage and usually will be
higher than the battery’s resting voltage.
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 31 32

Comments to this Manuals

No comments